Products
Fire Resistant Cables (BS EN 50525-3-31)

Fire Resistant Cables (BS EN 50525-3-41)

Mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants,hotels, hospitals and high-rise buildings.

Construction

Conductor : Copper conductor according to BS EN 60228 class 1/5.

Fire Barrier : Mica glass tape.

Insulation : Crosslinked polyolefin material type EI 5 according to EN 50363-5.

Insulation Option : UV resistance, hydrocarbon resistance, oil resistance, anti-rodent and anti-termite

properties can be offered as option.

Standards

BS EN 50525-3-41

 

300/500V Mica+LSZH Insulated, Non-sheathed Power Cables to BS EN 50525-3-41 (Single Core)

Conductor

FFX100 05mZ-U/K

No. of Cores × Cross-sectional Area

Conductor Class

Nominal Insulation Thickness

Min. Overall Diameter

Max. Overall Diameter

Approx. Weight

No.×mm²

 

 

mm

mm mm

kg/km

1×0.5

1

0.6

2.9

3.4

13.5

1×0.75

1

0.6

3.1

3.6

16.5

1×1.0

1

0.6

3.2

3.8

19.7

1×0.5

5

0.6

3.1

3.6

14.2

1×0.75

5

0.6

3.2

3.8

17.7

1×1.0

5

0.6

3.4

3.9

20.7

450/750V Mica+LSZH Insulated, Non-sheathed Power Cables to BS EN 50525-3-41 (Single Core)

Conductor

FFX100 07mZ-U/R/K

No. of Cores × Cross-sectional Area

Conductor Class

Nominal Insulation Thickness

Min. Overall Diameter

Max. Overall Diameter

Approx. Weight

No.×mm²

 

mm

mm

mm

kg/km

1×1.5

1

0.7

3.6

4.3

22

1×2.5

1

0.8

4.2

5.0

35

1×4

1

0.8

4.6

5.6

52

1×6

1

0.8

5.1

6.2

73

1×10

1

1.0

6.3

7.6

122

1×1.5

2

0.7

3.7

4.4

24

1×2.5

2

0.8

4.3

5.1

37

1×4

2

0.8

4.8

5.7

54

1×6

2

0.8

5.3

6.4

76

1×10

2

1.0

6.6

8.0

127

1×16

2

1.0

7.4

9.0

191

1×25

2

1.2

9.1

11.1

301

1×35

2

1.2

10.0

12.3

405

1×50

2

1.4

11.6

14.2

550

1×70

2

1.4

13.1

16.1

774

1×95

2

1.6

15.1

18.6

1069

1×120

2

1.6

16.6

20.4

1333

1×150

2

1.8

18.3

22.6

1640

1×185

2

2.0

20.3

25.1

2055

1×240

2

2.2

23.0

28.5

2690

1×300

2

2.4

25.5

31.6

3364

1×400

2

2.6

28.5

35.3

4252

1×500

2

2.8

31.5

39.2

5343

1×630

2

2.8

35.0

43.5

6868

1×1.5

5

0.7

3.8

4.5

23

1×2.5

5

0.8

4.4

5.3

37

1×4

5

0.8

4.9

5.9

54

1×6

5

0.8

5.4

6.5

76

1×10

5

1.0

6.7

8.1

128

1×16

5

1.0

7.7

9.4

191

1×25

5

1.2

9.4

11.6

297

1×35

5

1.2

10.7

13.1

403

1×50

5

1.4

12.5

15.4

577

1×70

5

1.4

14.2

17.6

803

1×95

5

1.6

16.1

19.8

1066

1×120

5

1.6

17.7

21.9

1332

1×150

5

1.8

19.6

24.3

1660

1×185

5

2.0

21.6

26.8

2030

1×240

5

2.2

24.5

30.4

2659

600/1000V Mica+LSZH Insulated, Non-sheathed Power Cables to BS EN 50525-3-41 (Single Core)

Conductor

FFX100 1mZ-R

No. of Cores × Cross-sectional Area

Conductor Class

Nominal Insulation Thickness

Nominal Overall Diameter

Approx. Weight

No.×mm²

 

mm

mm

kg/km

1x1.5

2

0.7

4.1

27

1x2.5

2

0.8

4.7

39

1x4.0

2

0.8

5.3

57

1x6.0

2

0.8

5.8

78

1x10

2

1.0

7.2

125

1x16

2

1.0

8.2

186

1x25

2

1.2

10.0

291

1x35

2

1.2

11.2

382

1x50

2

1.4

13.0

517

1x70

2

1.4

15.0

728

1x95

2

1.6

17.0

1003

1x120

2

1.6

19.0

1239

1x150

2

1.8

21.0

1529

1x185

2

2.0

23.0

1910

1x240

2

2.2

26.0

2492

1x300

2

2.4

29.0

3113

1x400

2

2.6

32.5

3964

1x500

2

2.8

36.0

4965

1x630

2

2.8

40.0

6376

Inquiry

Please Feel free to give your inquiry in the form below.we will reply you in 24 hours.

    • *

    • *

    • *